Haltech Wideband Controller
(HWC)
Manual
Warning!
The Oxygen Sensor used in this device gets very hot in operation.
Do not touch the hot sensor. Do not let a hot sensor touch a
combustible surface. Do not use the sensor with or near flammable
liquids or gases. Failure to heed these warnings may result in severe
burns, explosions or fires.
When installed in the exhaust, the oxygen sensor MUST be
connected and operating whenever the car is running. An un-
powered oxygen sensor will be quickly damaged when exposed to
hot exhaust gases.
Haltech_Wide_Band_Manual_1.0.doc
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Warning!

Haltech Wideband Controller (HWC) Manual Warning! The Oxygen Sensor used in this device gets very hot in operation. Do not tou

Strany 2

5. Calibration There are two types of calibration for the HWC: free air calibration and sensor heater calibration. Sensor heater calibration and fir

Strany 3 - 1. Overview

6. Remote display and recording of Lambda and/or AFR In many applications it may be desirable to monitor the air-fuel data remotely using a dash-mou

Strany 4 - - 4

6.3 Haltech Digital Display (HDD) 1. Connect the Serial OUT connection (unmarked) to the Serial IN connection of the HDD1 (marked) with the included

Strany 5

8. Tips, Tricks and Troubleshooting 8.1 General measurement requirements The HWC measures the air-fuel-ratio by measuring the amount of oxygen in th

Strany 6 - TURBO CHARGED vehicles:

8.7 Sensor Timing Errors These errors are typically encountered when the sensor does not have outside air available as reference gas. If you encount

Strany 7

Note: The analog outputs are NOT designed to power other devices or sensors. So using the flat-line setting at 5V and expecting to power a sensor fr

Strany 8

b. Vehicle has a 2-wire sensor: While the engine is off determine which of the 2 wires has a low resistance between the wire and the sensor body. This

Strany 9 - 4. First Time Use

Appendix B: LED blinking codes 1. Blinking steady about 2 times/second: Warming up 2. Blinking steady at about 4 times/second: Heater calibration

Strany 10 - 5. Calibration

Appendix C: HWC Error Codes and Troubleshooting Tips Error Code Error Message Likely Root Cause Fix Error 1 Heater circuit shorted 1. Short in

Strany 11

Appendix C: Limited Warranty LIMITED WARRANTY Haltech stands behind the quality of its products. Haltech makes the following warranty to purchasers

Strany 12

1. Overview... 3 2

Strany 13

Revision History 1.0 – 12/05/05 Initial release - 20 -

Strany 14 - 8.7 Sensor Timing Errors

1. Overview The HWC is a stand-alone Wideband Controller used to measure the Air/Fuel Ratio (AFR) or Lambda for an engine. For gasoline-driven engine

Strany 16

3. Mounting and Connecting the Wideband Controller 1. Find a suitable location under your vehicle where the Controller body can be mounted. Using zip

Strany 17

3.1 Indicator LED and Calibration button hookup: Any color LED can be used. A typical LED has 2 wires called Anode and Cathode. The Cathode side is

Strany 18

Do NOT install the Bung below the 3 o'clock or 9 o'clock position. Condensation can form in the exhaust pipe and permanently damage the se

Strany 19 - Disclaimer

3.3 How to fabricate a copper heat sink Use a 4” x 4” (10cm x 10 cm) sheet of copper sheet metal 14ga (1.5mm) thick. Drill a hole in the center with

Strany 20 - Revision History

4. First Time Use 1. Do not connect the sensor yet. 2. Switch 12V supply to the HWC on and wait for 10 seconds. 3. Switch the 12V supply off af